the global source for passive network materials
Products
Search   < Back

Type N Female for 1/4" FSJ1-50A cable

(Code: F1PNF)
Add to Enquiry List
Type N Female for 1/4" FSJ1-50A cable

Product Classification  
Brand   HELIAX®
Product Type   Wireless and radiating connector

General Specifications  
Interface   N Female
Body Style   Straight
Mounting Angle   Straight

Electrical Specifications  
Connector Impedance   50 ohm
Operating Frequency Band   0 – 8000 MHz
Average Power at Frequency   0.4 kW @ 900 MHz
Cable Impedance   50 ohm
3rd Order IMD, typical   -112 dBm @ 910 MHz
3rd Order IMD Test Method   Two +43 dBm carriers
RF Operating Voltage, maximum (vrms)   565.00 V
dc Test Voltage   1600 V
Outer Contact Resistance, maximum   0.25 mOhm
Inner Contact Resistance, maximum   1.00 mOhm
Insulation Resistance, minimum   5000 MOhm
Peak Power, maximum   6.40 kW
Shielding Effectiveness   -110 dB

Mechanical Specifications  
Outer Contact Attachment Method   Self-clamping
Inner Contact Attachment Method   Solder
Outer Contact Plating   Silver
Inner Contact Plating   Gold
Interface Durability   500 cycles
Interface Durability Method   IEC 61169-4:17
Connector Retention Tensile Force   450 N   |   101 lbf
Insertion Force   124.55 N   |   28.00 lbf
Insertion Force Method   IEC 61169-16:9.3.5
Pressurizable   No
Coupling Nut Proof Torque   1.70 N-m   |   1.25 ft lb
Coupling Nut Proof Torque Method   IEC 61169-16:9.3.11
Coupling Nut Retention Force   445.00 N   |   100.04 lbf
Coupling Nut Retention Force Method   IEC 61169-16:9.3.11

Dimensions  
Nominal Size   1/4 in
Diameter   15.83 mm   |   0.62 in
Height   15.83 mm   |   0.62 in
Length   55.19 mm   |   2.17 in
Weight   100.46 g   |   0.22 lb
Width   15.83 mm   |   0.62 in

Environmental Specifications  
Operating Temperature   -55 °C to +85 °C (-67 °F to +185 °F)
Storage Temperature   -65 °C to +125 °C (-85 °F to +257 °F)
Immersion Depth  1 m
Immersion Test Mating   Mated
Immersion Test Method   IEC 60529:2001, IP68
Moisture Resistance Test Method   IEC 60068-2-3
Mechanical Shock Test Method   IEC 60068-2-27
Thermal Shock Test Method   IEC 60068-2-14
Vibration Test Method   IEC 60068-2-6
Corrosion Test Method   IEC 60068-2-11

Standard Conditions  
Attenuation, Ambient Temperature   20 °C   |   68 °F
Average Power, Ambient Temperature   40 °C   |   104 °F
Average Power, Inner Conductor Temperature   100 °C   |   212 °F

Return Loss/VSWR
Frequency Band VSWR Return Loss (dB)
45–4100 MHz 1.12 25.00
4100–6200 MHz 1.17 22.00
6200–11000 MHz 1.43 15.00

Regulatory Compliance/Certifications
Agency Classification
RoHS 2011/65/EU Compliant by Exemption
ISO 9001:2015 Designed, manufactured and/or distributed under this quality management system
China RoHS SJ/T 11364-2014 Above Maximum Concentration Value (MCV)