the global source for passive network materials
Products
Search   < Back

ST212 8 Core

(Code: 101-1208-083)
Add to Enquiry List
ST212 8 CoreMULTICOAXIAL/R-02Y(St)CHH 8x0.40S



Description

Tinned copper conductor. Foam polyethylene insulation. Aluminium-polyester-aluminium foil shield. Tinned copper braid shield. Halogen free compound outer sheath. Lay up coaxials. Polyester foil protection. Halogen free compound outer sheath.

PHYSICAL CHARACTERISTICS
Conductor
    Material Tinned copper
    Section (mm2) 0,12
    AWG 26
    Composition 1x0,4
Insulation
    Material Foam polyethylene
    Diameter (mm) 1,90
    Colour natural
Semiconductor shield
     Material -
     Diameter (mm) -
     Colour -
Individually shield
    Drain wire
        -Section (mm2) -
   -AWG -
   -Composition -
1st Shield
    -Material Aluminium-polyester-aluminium foil
    -Coverage (%) 100
2nd Shield
    -Material Tinned copper braid
    -Coverage (%) 89
Individually outer sheath
     Material Halogen free compound
     Diameter (mm) 3,10
     Colour Grey RAL 7001 numbered
Lay up
    Composition (1+R)+7
    Diameter (mm) 10,08
Protection
     Composition Polyester foil
Inner sheath
     Material -
     Diameter (mm) -
     Colour -
Common shield
    Drain wire
    -Section (mm2) -
    -AWG -
    -Composition -
    Shield
    -Material  -
    -Coverage (%) -
Outer sheath
     Material
     Diameter (mm
     Colour
MECHANICAL CHARACTERISTICS
    Appox. Weight 164,1 Kg/Km
    Operating temperature range -40 / + 70 ºC
    Minimum bending radius 236 mm
ELECTRICAL CHARACTERISTICS
    Conductor DC resistance at 20º C 147,2 Ω/Km
    Shield DC resistance at 20º C (Individually) 23,7 Ω/Km
    Shield DC resistance at 20º C (Common -
    Nominal capacitance 56 pF/m
    Nominal impedance 75 Ω
    Velocity of propagation 80%
    Insulation resistance >10000 >10000
    Voltage test 1500V
    Attenuation Frequency (MHz) dB/100 m
1 1,7
4 3,6
10 5,5
50 12,0
70 14,0
100 16,6
    Return loss Frequency (MHz) dB
0-800 20
800-1000 23
SAFETY FLAME TEST
    Test for vertical flame spread IEC-60332-1
    Test for vertical flame spread IEC-60332-2
    Test for vertical flame spread IEC-60332-3
    It does not emite toxic fumes or halogens IEC-754-1
    It does not emite corrosive fumes or halogens IEC-754-2
    Low emision of dense fumes IEC-1034-1
ENVIRONMENT
    Content of hazardous sustances Directive 2002/95/CE
APPLICABLE SPECIFICATIONS
    Conductor material UNE-EN 60228
    Insulation material UNE-EN 50290