Environmental Specifications |
Performance Property |
ºF |
ºC |
Installation Temperature Range |
-40/+185 |
-40/+85 |
Storage Temperature Range |
-94/+185 |
-70/+85 |
Operating Temperature Range |
-40/+185 |
-40/+85 |
Construction Specifications |
Description |
Material |
In. |
(mm) |
Inner Conductor |
Stranded BC |
0.176 |
(4.47) |
Dielectric |
Foam Polyethylene |
0.455 |
(11.56) |
Outer Conductor |
Aluminum Tape |
0.461 |
(11.71) |
Overall Braid |
Tinned Copper |
0.490 |
(12.45) |
Jacket |
Black Thermoplastic Elastomer |
0.590 |
(14.99) |
Mechanical Specifications |
Performance Property |
Units |
US |
(metric) |
Bend Radius: installation |
in. (mm) |
1.5 |
(38.1) |
Bend Radius: repeated |
in. (mm) |
6.0 |
(152.4) |
Bending Moment |
ft-lb (N-m) |
1.75 |
(2.37) |
Weight |
lb/ft (kg/m) |
0.165 |
(0.25) |
Tensile Strength |
lb (kg) |
350 |
(158.9) |
Flat Plate Crush |
lb/in. (kg/mm) |
40 |
(0.71) |
Electrical Specifications |
Performance Property |
Units |
US |
(metric) |
Velocity of Propagation |
% |
87 |
|
Dielectric Constant |
NA |
1.32 |
|
Time Delay |
nS/ft (nS/m) |
1.17 |
(3.83) |
Impedance |
ohms |
50 |
|
Capacitance |
pF/ft (pF/m) |
23.4 |
(76.6)
|
Inductance |
uH/ft (uH/m) |
0.058 |
(3.83)
|
Shielding Effectiveness |
dB |
>90 |
|
DC Resistance |
|
|
|
Inner Conductor |
ohms/1000ft (/km) |
0.43 |
(1.42) |
Outer Conductor |
ohms/1000ft (/km) |
1.2 |
(3.9) |
Voltage Withstand |
Volts DC
|
4000 |
|
Jacket Spark |
Volts RMS |
8000 |
|
Peak Power |
kW |
40 |
|
|